The Sentry Model HM-501 Dual Serial Interface Card
provides 2 serial data channels utilizing RS-485 or RS422 data standards. Each
channel can be independently addressed and configured for half-duplex (RS-485) or
full-duplex (RS-422) operation. Jumpers are provided to choose the type of
communication (half/full-duplex) and IRQ if required.
Each, port when configured for half-duplex
operation, can communicate with 63 addressed Sentry devices, such as Host Panels (Model
HM-527), Utility Panels (Models HM-610/612), and Power Supplies (Model HM- 535). Alternately,
the port can communicate with a maximum of 16 Remote LCD Displays Model HM-676).
Each port can also be configured for full-duplex
communication for use in Sentry systems requiring Host - Remote Console communication
The Model HM-501 communicates with differential data
signals following the EIA standards described for RS-485 / RS-422. A typical data line can
extend over 4000 feet and does not require special line terminations.
The dual channel card is equipped with two 9 pin sub
D connectors with the pin out connections detailed in the HM-501 Installation and Service
Manual.
To estimate the number of Dual Serial cards required
for a particular installation, refer to the Model HM-550 Master Controller Technical
Specification. For installations with greater than 416 apartments, the Model
HM-502
Quad Serial Interface Card or Model HM-503 Quad Isolated Serial Interface Card should be
used, contact the factory for details.