- MICROCOMPUTER CONTROLLED
- POWERS, MONITORS, AND
SUPERVISES SMOKE DETECTORS and
EMERGENCY CALL PULL CORD / BED CORD
- RESIDENT ASSURANCE CHECK-IN FEATURE
- LED TEST & STATUS INDICATORS
- WIRELESS REMOTE PENDANT INPUT
- SECURITY INPUT
- DOME LIGHT OR STROBE CONTROL
|
HM-527 Rev F
Front View
Click pic for larger view
|

HM-527 Rev F
Rear View
Click pic for larger view |
|
DESCRIPTION:
The
Sentry HM-527 Host Panel is the master panel to all other devices in a
residence. It powers, monitors and supervises smoke detectors, call switches,
pendant receivers and security keypad. The panel attaches to a wall mounted, two gang
electrical box. Internal microcomputer monitors all inputs, provides a self test, and
communicates with master console. The panel incorporates an emergency pull cord, assurance
check-in button, and LED operational indicators. A supervised DC power output is provided
for powering a remote smoke detector.
INPUTS:
Inputs to the remote devices are wired through the
panel's connector. Wire connections are provided for the smoke detector (model HM-560B),
remote emergency pull station, security devices, intercom, and wireless pendant receiver.
All devices wired to the inputs are supervised by the panel.
WIRING:
The Host Panel connects to the Master Console and
power supply with a 2 pair wire. Up to 51 Host Panels can connect to the same data cable,
see wire design guide: 390-108. For ease of installation and maintenance, the Host panel
mates with the prewired connector, Model HM-582.
INDICATORS:
A LED will flash green to indicate proper system
operation via a built-in self test feature. A red LED indicates when an emergency call is
initiated and verified by the console. A second red LED indicates the assurance period is
active and will extinguish when the check-in button is pressed. To simplify
installation and service, both red LED's blink every 30 seconds to indicate proper panel
operation without data communication to the console.
EMERGENCY CALL:
The Host Panel is equipped with a 45" nylon
pull cord. The LED indicator will glow red when the emergency call switch is operated and
verified by the console.
PANEL COLOR:
The standard
HM-527 has an off-white plate with a beige
colored panel overlay. The panel overlay can be special ordered with custom colors or
artwork. Contact Sentry for additional information.
TERMINATIONS:
The Host Panel connects to all wiring via the 15
conductor, pre-wired connector, part no. HM-582.
|
RESIDENT ASSURANCE:
The
HM-527 host panel will include a Check-In pushbutton and assurance LED indicator. The LED will light to indicate the assurance
period is activated. When the resident presses the Check-In button, the indicator will go
off until the next assurance period. If this button has not been operated by the end of
the assurance period, the apartment number will be displayed on an assurance list at the
master console.
The Check-In button is also used to reactivate an
apartment from the vacation mode.
REMOTE EMERGENCY CALL OPTION:
The model
HM-527 Host Panel can connect to unlimited
number of Model HM-41 Remote Emergency Call stations. The LED on the host panel, as well as
the remote station will light to indicate that an emergency call was received at the
master console. All remotes' are supervised by the host panel. A wireless remote pendant
is available (model HM-546) for initiating an emergency call from anywhere in the apartment.
For best reception, the pendant receiver (model HM-547) is usually located near the smoke
detector.
PANEL FINISH AND DIMENSIONS:
High impact injection molded ABS housing finished in
a non-glare off-white. Maximum panel dimensions are 4.7"W X 4.6"H X 1.50"D.
The front surface of the panel will extend ½" from finished wall.
OPTIONS TO REV F PANEL:
Latest version host panel HM-527 Rev F provides an option for two types of smoke
detectors. Type "A" for 6 wire smoke detector that has a signal and ground
lead for tandem smoke detector operation. Type "B" for commercial 4-wire
smoke detectors with integral sounders that uses reverse polarity on the power
leads for tandem operation. Second option provides a End Of Line resistor
across the auxiliary input when the input is not used. Both options are
field selectable through dip switch settings.
INSTALLATION:
The Host Panel is wall mounted with center up to
48" above finished floor in an unobstructed location. The electrical box should be
4" square by 2" deep, with a ½" raise, two gang plaster ring. The nylon
pull cord will extend to within 2" above finished floor. When the panels are mounted
lower on the wall, the installer should tie another knot in the cord at 2" above the
floor, and cut off the excess cord.
The Model
HM-527 can be special ordered with an
auxiliary connector for wiring to the Model HM-544 Remote Check-In Station. This special order is also necessary when a motion detector is used
for automatic check-in.
|