Sentry System OverviewCommon EquipmentConsole EquipmentSentry Miscellanous Equipment

SYSTEM OVERVIEW
RESIDENCE EQUIPMENT


HOST PANEL
The intelligent addressable Sentry Legacy host panel is the primary unit in each apartment. It is equipped with an emergency pull cord and a check in (assurance) button. The check in button also functions as the emergency call cancellation switch.
The intelligent Sentry Legacy host panel provides four inputs and two outputs. Devices wired to the emergency and smoke inputs are supervised. The host panel monitors all inputs, provides a self-test and communicates with the master console. Surge suppression and voltage transient protection is provided in each panel. The host panel connects to all wiring via a 15 conductor pre-wired connector. LED's provide indication of assurance reminder, call verification, and data presence.
Host panel connectors provide wiring connections for the following options:

REMOTE EMERGENCY CALL SWITCH
This pull cord station extends the emergency call function to other rooms in the residence. It contains a nylon pull cord and call verification LED indicator.

SMOKE DETECTOR
The photoelectric smoke detector is low voltage, line powered designed for single and multiple station use. The power comes directly from the Sentry Legacy power supplies, which provide continuous power when utility power is interrupted. The smoke detectors come equipped with their own 85 decibel temporal pattern horns. The smoke alarm is announced as a smoke alarm (versus an emergency call). Multiple detectors in an apartment are wired for tandem operation, if one sounds, all sound.

WIRELESS PENDANT
Each residence can be equipped with a wireless receiver/transmitter to provide a wireless, remote emergency call function. The receiver connects to the host panel and duplicates the emergency call function of the pull cord.

SECURITY
Magnetic contacts, PIR motion detection devices or other security devices can be attached to the Sentry Legacy host panel in each residence to initiate a unique security announcement alarm.

BED CORD
Pendant push button bed-cords can be provided in place of the pull-cords.

DOME LIGHT
A dome light outside each apartment which lights when an emergency call is placed can be installed.

STROBE LIGHT
Strobe lights are used in conjunction with the smoke detector horn when in alarm for the hearing impaired.

CO (Carbon Monoxide) MONITOR
A carbon monoxide detector can be connected into the Sentry Legacy system. This is required in some states.

 

 

 
 

 